Electromagnetic flowmeters have no moving parts that obstruct or restrict the flow. The device isolates the electronic environment from the area being measured and provides easy wiring. Common uses to measure Water, Wast water, ETP Inlet, Outlet etc in Pharmaceuticals, Textiles, Food and Beverage, Paper and Pulps etc sector in  Bangladesh.

1. Electromagnetic Flow Meter
Measurement
Range
From 0.1 m / s to 10 m / s; 0.0045 m3 to 113 094 m3 (according to pipe dimensions) DN-15 to 1000
Measurement Field Liquids
Body Material Aluminum Alloy
Sensor Material SUS304 / AISI 316; or optional: HastelloyC, HastelloyB, Titanium,
Tantalum, Platinum
Inner Coating
Material
Teflon (PTFE), or Rubber
Temperature
Range
-20 ° C / 60 ° C Rubber, -20 ° C / + 150 ° C Teflon (PTFE)
Precision 0.2% High Sensitivity
Measurable Conductivity Minimum 20 uS / cm
Connection Flange Connection
Protection Class IP65, or optional IP67, IP68
Output Pulse, Analog (isolated 4-20mA, 0-10 V or Frequency), RS485, RS232C,
HART, Profibus and Alarm Relay Output
Indicator 2x16 Alphanumeric Characteristic, Backlit LCD Display with
Instantaneous and Total Flow